The LN50 HyperCore High Wall sets a new standard in unparalleled design and customised home comfort; with advanced features such as 3D i-See Sensor Technology, patented Dual Barrier Coating, Plasma Quad Plus Filtration and Dual Split Vane Technology. With HyperCore Technology, it delivers New Zealand's best heat pump performance in cold conditions; providing its full rated heating capacity right down to -15°C and guaranteed heating operation down to -25°C. Boasting improved energy efficiency with R32 refrigerant and a sleek, premium finish, the LN HyperCore Series truly redefines the heat pump.

Cooling Capacity5.0 kW
Heating Capacity6.0 kW
Select a Size
Select a Colour
Select a Controller
Looking for the previous version of this model?
View - MSZ-LN50VGV

Features

3D i-See Sensor

The unique 3D i-See Sensor continuously analyses the temperature profile of your room, detecting exactly where you and your family are located based on your unique body heat signatures. With this thermal data, it then directs the perfect amount of heating or cooling towards those who need it most.

HyperCore Guaranteed Full Rated Heating to -15°C

While ordinary heat pumps produce less heat below 7°C, only Mitsubishi Electric HyperCore Technology guarantees to continue to deliver its full rated heating capacity right down to -15°C, so you stay warm when you need it most.

Dual Barrier Coating

The patented and world’s first Dual Barrier Coating from Mitsubishi Electric prevents dust and dirt from accumulating on the inner surface of the indoor unit; keeping your heat pump clean year-round. Keeping key internal components like the heat exchanger, fan and internal duct clean is important for both home comfort and efficiency. Not only does dust and dirt build-up typically create unpleasant odours, it also forces a heat pump to work harder, which can result in significantly impaired energy efficiency.

Plasma Quad Plus Filtration

The new Plasma Quad Plus Filter effectively removes six types of air pollutants including bacteria, allergens, airborne contaminants, mould, dust and micro particles with up to 99.7% efficiency; for a cleaner, healthier living space.

Dual Split Vane Technology

With the ability to create various airflow patterns, both horizontal and vertical, every person in a room can be comfortable.

Premium Coloured Finish

The Black Diamond LN Series comes in a range of stunning colour options including White Diamond, Red Diamond and Black Diamond, in a premium gloss finish. The matching wireless controller adds a cohesive, stylish touch to your interior design.

Backlit 7-Day Programmable Controller

The Backlit 7-Day Programmable Controller features a built-in weekly timer, allowing you to program up to four time and temperature settings for each day of the week. You can now return to comfort without having to manually adjust the temperature. Perfect for anyone with a busy lifestyle, the Backlit 7-Day Controller is a great way to regulate your energy usage without compromising on comfort.

Indirect/Direct Mode

The Indirect/Direct Mode offers finely-tuned operation by locating where an occupant is in the room. Airflow is then directed either in the area surrounding the occupant to avoid excessive heating or cooling, or directly towards the occupant for immediate comfort, as set by user.

Specifications

MSZ-LN50VG2V // HyperCore LN50 High Wall Heat Pump System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 5.0 kW · Capacity - Heating: 6.0 kW
· Capacity - Cooling (min. - max.): 1.4 - 5.8 kW · Capacity - Heating (min. - max.): 1.8 - 9.0 kW
· Power Input - Cooling: 1.38 kW · Power Input - Heating: 1.50 kW
· Star rating - Cooling: Current 3.0, Seasonal 3.5 · Star rating - Heating: Current 3.5, Seasonal 2.5
· EER / COP: 3.62 / 4.00 · AEER / ACOP: 3.61 / 3.99
· Sensible - Cooling: 3.85 kW · Dry Mode (Moisture Removal, Litre/hr): 1.70
· Current - Cooling [In+Outdoor] (Rated): 6.3 A · Current - Heating [In+Outdoor] (Rated): 6.8 A
HyperCore Performance
· @ -0 degC Capacity - Heating: 6.0 kW · @ -5 degC Capacity - Heating: 6.0 kW
· @ -10 degC Capacity - Heating: 6.0 kW · @ -15 degC Capacity - Heating: 6.0 kW
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -25 / +24 degC

MSZ-LN50VG3V-A1 - Wall Mounted Indoor Unit - Pearl White

· Function: Cooling/Heating · Type: Single Split, Inverter
Nominal Capacity
· Capacity - Cooling: 5.0 kW · Capacity - Heating: 6.0 kW
· Sound Level - Cooling (Low - Super High, dB(A)): 27 / 31 / 35 / 39 / 46 · Sound Level - Heating (Low - Super High, dB(A)): 25 / 29 / 35 / 43 / 47
· Air Volume - Cooling (Super High, Litre/sec): 232 · Air Volume - Heating (Super High, Litre/sec): 255
· Refrigerant: R32 · Liquid Pipe Size (OD, mm): 6.35
· Gas Pipe Size (OD, mm): 9.52 · Max. Pipe Length (m): 30
· Max. Pipe Height (m): 15 · Power Supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 890 x 233 x 307 · Weight: 16.0 kg

MUZ-LN50VGHZ2-A2 - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -25 / +24 degC
· Sound Level - Cooling (dB(A)): 51(64) · Sound Level - Heating (dB(A)): 55
· Air Volume - Cooling (Litre/sec): 95-232 · Air Volume - Heating (Litre/sec): 82-255
· Power Supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid Pipe Size (OD, mm): 6.35 · Gas Pipe Size (OD, mm): 9.52
· Max. Pipe Length (m): 30 · Max. Pipe Height (m): 15
· Dimensions (WxDxH, mm): 840 x 330 x 880 · Weight: 55 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]

Downloads

Support

Optional

Optional Accessories

Our PAR40 wired seven day controller with backlit LCD screen allows you to program up to eight separate start/stop patterns per day over a week.
The award-winning MAC-568IF-E Wi-Fi Interface connects discreetly to your heat pump’s control board and should only be installed by an authorised installer. The MAC-568IF-E Wi-Fi Interface is available on Mitsubishi Electric High Wall, Floor Mounted, and Ducted Heat Pumps, and can either be purchased as an optional upgrade at time of purchase, or retrofitted to an existing Mitsubishi Electric model.
MA, M-NET and Contact Terminal Interface. Has remote on/off, prohibit/permit control and run/error outputs - all outputs require an independent external 12VDC power supply. Used to connect PAR-21 / PAR-31 to; MSZ-GE/FB/EF, MFZ-KA/FB & SLZ-KA~VAL indoor units or a Central / Schedule Controller to each indoor unit connected to a M or S-Series outdoor unit.
*Please note that due to the reflective and multilayered finish of the Black Diamond Series indoor units, the colours shown within this brochure are indicative only. While every effort has been made to display the units as they appear in person, due to variables such as lighting and positioning affecting the appearance, we recommend viewing the Black Diamond Series at your nearest showroom.
Black Diamond LN Series