Ducted PEA140 Heat Pump with Wi-Fi

Large Room System // PEA-M140GAA + MAC-588IF-E

The ducted PEA-M140’s high static airflow allows air to be directed to different areas of your home or office with ease. This unit is ideal for heating or cooling a large number of rooms at once. Includes PAR Wired Controller. The Wi-Fi range comes equipped with a Wi-Fi Control Interface (supplied separately), allowing you to control and monitor your heat pump from anywhere via your smartphone, tablet or online account.

Cooling Capacity14.0 kW
Heating Capacity16.0 kW
Select a Size - R32 Refrigerant
Select a Controller
Optional Outdoor Performance

Features

Heat or cool your whole home with a central heating ducted heat pump system

Mitsubishi Electric Ducted Heat Pump Systems are the ultimate solution for unobtrusive, whole home comfort. Designed for easy installation in ceiling or bulkhead spaces, ducted heat pumps are largely hidden from view, with only subtle grilles visible. Using concealed ducting to connect multiple rooms for heating or cooling, these systems are ideal for residential or commercial applications.

Combining with optional Lossnay Fresh Air Ventilation

The Mitsubishi Electric Lossnay system is an energy recovery ventilation solution that can be integrated with the PEAD Ducted Heat Pump. The two systems will work together to further increase energy savings while ventilating your home to remove stale air and control moisture. The Lossnay system will recover the energy from stale air to pre-heat or pre-cool incoming fresh air, reducing the amount of additional heating or cooling required. Both systems can be controlled from one central wall mounted controller for optimum ease of use. Why you need energy recovery ventilation and how it works with a ducted heat pump.

Unobtrusive, Whole Home Heating

Our ducted systems are specifically designed for installation in ceiling spaces. Ideal for large residences or offices, ducted units are the ultimate hidden heating and cooling solution with only grilles visible.

Next-Generation R32 Technology

R32 is a refrigerant with just one-third the global warming potential of R410A and has zero ozone depletion potential. R32 offers increased energy efficiency, and is said to be the next generation of refrigerants.

Ideal Airflow

The flexible duct design and high-pressure of our ducted systems increase variation in airflow options ensuring the system operates in a way that best suits virtually all room layouts.

Includes the Wi-Fi Control Interface

Locally developed to suit the busy lifestyles of New Zealanders, award-winning Wi-Fi Control unlocks the door to smarter heating. This innovative technology allows you to control or monitor your heat pump from anywhere via your smartphone, tablet or online account. Wi-Fi Control allows you to control your system remotely, develop operating rules, and set minimum and maximum room temperatures for healthy and comfortable living.

Read more and try a demonstration

Deluxe PAR Weekly Controller

This attractive full dot liquid crystal display incorporates a large backlit screen and simple menus for easy operation.
You can set up to 8 temperature and airflow patterns per day for seven days, allowing you to reduce your energy consumption when needed, saving you both time and money. Perfect for the busy home, workplace or retail store.

Click here to find out more

Optional Zone Controller Upgrade

Transform your ducted system. With the ability to control up to 8 zones, expanded functionality and interaction, intuitive airflow control, and temperature, occupancy and brightness sensors – the PAC-ZC Zone Controller brings intuitive, yet simple control to a whole new level.

Click here for optional Zone Controllers

Specifications

PEA-M140GAA + MAC-588IF-E // Ducted PEA140 Heat Pump with Wi-Fi

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 14.0 kW · Capacity - Heating: 16.0 kW
· Capacity - Cooling (min. - max.): 6.2 - 15.3 kW · Capacity - Heating (min. - max.): 5.7 - 18.0 kW
· Power Input - Cooling: 4.10 kW · Power Input - Heating: 3.90 kW
· Star rating - Cooling: NA · Star rating - Heating: NA
· EER / COP: 3.41 / 4.10 · AEER / ACOP: 3.33 / 3.99
· Current - Cooling [In+Outdoor] (Rated): 18.70 A · Current - Heating [In+Outdoor] (Rated): 17.70 A
· Current (Max.): 32.86 A
Performance
· Operation Range - Cooling: -5 / +52 degC · Operation Range - Heating: -20 / +21 degC

PEA-M140GAA.TH - Ducted Indoor Unit

· Function: Cooling/Heating · Type: Single Split, Inverter
Nominal Capacity
· Capacity - Cooling: 14.0 kW · Capacity - Heating: 16.0 kW
· Sound Level - Cooling (Low - Super High, dB(A)): 42 - 45 · Sound Level - Heating (Low - Super High, dB(A)): 42 - 45
· Air Volume - Cooling (Super High, Litre/sec): 1000 · Air Volume - Heating (Super High, Litre/sec): 1000
· Refrigerant: R32 · Liquid Pipe Size (OD, mm): 9.52
· Gas Pipe Size (OD, mm): 15.88 · Max. Pipe Length (m): 75
· Max. Pipe Height (m): 30 · Power Supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 1400 x 634 x 400 · Weight: 63.0 kg
· External Static Pressure: 50-100-150 Pa

PUZ-ZM140VKA-A.TH - R32 Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -5 / +52 degC · Operation Range - Heating: -20 / +21 degC
· Sound Level - Cooling (dB(A)): 50 · Sound Level - Heating (dB(A)): 52
· Air Volume - Cooling (Litre/sec): 2000 · Air Volume - Heating (Litre/sec): 2000
· Power Supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid Pipe Size (OD, mm): 9.52 · Gas Pipe Size (OD, mm): 15.88
· Max. Pipe Length (m): 75 · Max. Pipe Height (m): 30
· Dimensions (WxDxH, mm): 1050 x 330 x 1338 · Weight: 113 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]

Downloads

Support

Ducted PEA Series