Standard GS 35 High Wall Heat Pump

Small Room System // MSZ-GS35VFD-A1

The Standard GS35 High Wall Heat Pump offers real value and sets a new standard in super energy efficient heating and cooling. Next-generation EcoCore Technology is designed to use less power than ever before, and because they are very quiet, they are ideal where it matters most - in living rooms and bedrooms!

Cooling Capacity3.5 kW
Heating Capacity3.7 kW
Select a Size
Select a Controller

Features

Next Generation R32 Inverter Technology

Superior energy efficiency is achieved by incorporating a large, high-density heat exchanger, an advanced high-efficiency fan motor and a next-generation inverter compressor using the latest super efficient R32 refrigerant.

Blue Fin Outdoor Coil Protection

Slows the corrosion process on the heat exchanger, caused by salt and sulphur in the air, making it ideal for coastal and high sulphur areas.

Filtration for Cleaner Air

The standard air purifying filter traps dust, pollen and other airborne contaminants while the optional washable Anti-Allergy Enzyme Filter effectively breaks down harmful microbes such as bacteria, mould and dust mites.

Econo Cool

Econo Cool maximises energy efficient cooling. The target room temperature is automatically switched to Swing Mode to create a cooling breeze effect.

Vertical Swing Vane Airflow

The Vertical Swing Vane function enables airflow direction to be adjusted
up, down or set to Swing Mode – ensuring every corner of the room
is comfortable.

12 Hour Programmable Controller

With an easy-to-read display and large buttons, the hand-held 12 Hour Programmable Controller is designed to give you simplified control of your Standard GS Series High Wall.
Because the controller removes the complicated and focuses on the operating functions that really matter, whether you are tech savvy or not, you can rest assured comfort will always be at your fingertips.

Optional Deluxe PAR Weekly Controller

This optional weekly timer allows you to program up to four time and temperature settings for each day of the week. The 7-Day Controller is the perfect way to maximise energy efficiency without compromising on comfort.

Optional Wi-Fi Control Upgrade

Now you can pre-heat or cool a room no matter where you are. On the way home, running late, or in a different country, with optional Wi-Fi Control* you’ll always arrive home to total comfort.
*Wi-Fi adapter must be mounted externally.

Read more and try a demonstration

Optional Plasma Quad Connect for Healthier Air

Designed to integrate with your existing Standard GS Series Heat Pump, this high-performance two-stage advanced air filtration module, cleans and minimises dust and other allergens for better indoor air quality, all year round.

Learn more

Optional Corrosion Protection Service

This treatment service is considered to be mid-range corrosion protection which is suitable for many environments and will help increase the life of the Standard GS Series as well as reduce the likelihood of unsightly premature corrosion in less-than-ideal environmental conditions.
For further information, please contact your local Mitsubishi Electric representative.

Specifications

MSZ-GS35VFD-A1 // Standard GS 35 High Wall Heat Pump System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 3.5 kW · Capacity - Heating: 3.7 kW
· Capacity - Cooling (min. - max.): 1.1 - 3.7 kW · Capacity - Heating (min. - max.): 1.3 - 4.3 kW
· Power Input - Cooling: 0.95 kW · Power Input - Heating: 0.94 kW
· Current - Cooling [In+Outdoor] (Rated): 4.30 A · Current - Heating [In+Outdoor] (Rated): 4.30 A
Energy Rating Residential
· ZERL - Cooling (Cold/Mixed/Hot): 3.0 / 3.0 / 3.5 · ZERL - Heating (Cold/Mixed/Hot): 2.0 / 2.0 / 2.5
· TCSPF (Cold/Mixed/Hot): 4.64 / 4.53 / 5.06 · HSPF (Cold/Mixed/Hot): 3.55 / 3.90 / 4.17
· EER / COP: 3.68 / 3.94 · AEER / ACOP: 3.62 / 3.87
Energy Rating Commercial
· TCSPF (Cold/Mixed/Hot): 5.88 / 5.52 / 5.47 · HSPF (Cold/Mixed/Hot): 3.69 / 3.99 / 4.15
Performance
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC

MSZ-GS35VFD-A2 - R32 Wall Mounted Indoor Unit - White

· Function: Cooling/Heating · Type: Single Split, Inverter
Nominal Capacity
· Capacity - Cooling: 3.5 kW · Capacity - Heating: 3.7 kW
· Sound Level - Cooling (Low - Super High, dB(A)): 22 / 31 / 40 / 51 · Sound Level - Heating (Low - Super High, dB(A)): 23 / 30 / 37 / 45
· Air volume - Cooling (Super High, Litre/sec): 223 · Air volume - Heating (Super High, Litre/sec): 178
· Refrigerant: R32 · Liquid pipe size (OD, mm): 6.35
· Gas pipe size (OD, mm): 9.52 · Max. pipe length (m): 20
· Max. pipe height (m): 12 · Power supply: 230V / Single Phase / 50/60 Hz
· Dimensions (WxDxH, mm): 799 x 232 x 290 · Weight: 8.5 kg

MUZ-GS35VFD-A2 - R32 Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 51 · Sound Level - Heating (dB(A)): 51
· Air volume - Cooling (Litre/sec): 605 · Air volume - Heating (Litre/sec): 605
· Power supply: 230V / Single Phase / 50 Hz · Refrigerant: R32
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 9.52
· Max. pipe length (m): 20 · Max. pipe height (m): 12
· Dimensions (WxDxH, mm): 800 x 285 x 550 · Weight: 28.5 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]