RapidHeat KW60 Floor Console with Wi-Fi

Large Room System // MFZ-KW60VG + MAC-588IF-E

Featuring industry-leading RapidHeat Technology the RapidHeat KW60 provides optimum performance. With its slim and recessable design, the RapidHeat KW60 sits discreetly at floor level. Meanwhile, three uniquely shaped vanes control airflow to provide you with optimum air distribution that is customisable to your preference. The Wi-Fi range comes equipped with a Wi-Fi Control Interface (supplied separately) which allows you to control and monitor your heat pump from anywhere via your smartphone, tablet or online account.

Cooling Capacity6.1 kW
Heating Capacity6.5 kW
Select a Size
Select a Controller

Features

Rapid Heating

The Mitsubishi Electric RapidHeat Floor Console Series ensures the perfect room temperature is reached faster with new rapid heating technology. Advanced sensors coupled with Intuitive Control Logic mean optimal running temperatures are reached in the shortest amount of time possible with maximum energy efficiency. Automatically activated at start-up in low temperature conditions and when two way air flow is selected, warm air is blown in a downward direction first before the air is returned back into the indoor unit, where it is reheated a second time before it is released again. As a result, a room can now heat up to twice as fast in comparison to our previous model meaning our floor consoles are more energy efficient than ever.

Sleek, Sophisticated Design

Mitsubishi Electric RapidHeat Floor Consoles features clean, sharp lines creating streamlined, modern floor mounted heating. The removable base allows the RapidHeat Series to be recessed into your wall. This dramatically reduces the depth of the indoor unit from 215mm to 145mm - a decrease of 33%! The perfect solution for unobtrusive floor mounted heating or for new buildings and renovation projects.

Multi Vane Flow - Even Heat Distribution

The RapidHeat Series allows for complete customisation for ultimate comfort. The Multi Vane Flow function blows warm air in both an upward and downward direction, providing even and effective heating whilst also eliminating draughts. This is achieved via three uniquely shaped vanes that are designed for better airflow control and the freedom to customise them to your preference.

High Energy Efficiency

RapidHeat Floor Consoles (KW25/35/42/50/60) utilise advanced sensors with Intuitive Control Logic Technology to offer unparalleled low temperature heating performance in the shortest amount of time, whilst maintaining maximum energy efficiency. They also feature Econo Cool which switches airflow to Swing Mode; ensuring you use less energy to provide an overall cooling effect during the summer months.

R32 Refrigerant

R32 is a refrigerant with just one-third the global warming potential of R410A and has zero ozone depletion potential. R32 offers increased energy efficiency, and is said to be the next generation of refrigerants

RapidHeat technology for superior heating up to twice as fast

Specifications

MFZ-KW60VG + MAC-588IF-E // RapidHeat KW60 Floor Console with Wi-Fi System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 6.1 kW · Capacity - Heating: 6.5 kW
· Capacity - Cooling (min. - max.): 1.0 - 6.5 kW · Capacity - Heating (min. - max.): 1.2 - 8.8 kW
· Power Input - Cooling: 1.73 kW · Power Input - Heating: 1.88 kW
· Current - Cooling [In+Outdoor] (Rated): 7.7 A · Current - Heating [In+Outdoor] (Rated): 8.3 A
Energy Rating Residential
· ZERL - Cooling (Cold/Mixed/Hot): 2.5 / 2.5 / 2.5 · ZERL - Heating (Cold/Mixed/Hot): 2.0 / 2.5 / 3.0
· TCSPF (Cold/Mixed/Hot): 4.35 / 4.22 / 4.46 · HSPF (Cold/Mixed/Hot): 3.53 / 4.04 / 4.64
· EER / COP: 3.52 / 3.45 · AEER / ACOP: 3.50 / 3.44
Energy Rating Commercial
· TCSPF (Cold/Mixed/Hot): 5.07 / 4.77 / 4.72 · HSPF (Cold/Mixed/Hot): 3.85 / 4.30 / 4.66
Performance
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC

MFZ-KW60VG-A1 - DC Inverter Compact Floor Console

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 6.1 kW · Capacity - Heating: 6.5 kW
· Capacity - Cooling (min. - max.): 1.0 - 6.5 kW · Capacity - Heating (min. - max.): 1.2 - 8.8 kW
· Power Input - Cooling: 1.73 kW · Power Input - Heating: 1.88 kW
· Star rating - Cooling: 2.5 · Star rating - Heating: 2
· EER / COP: 3.52 / 3.45 · AEER / ACOP: 3.50 / 3.44
· Previous Star rating: N/A · Sensible - Cooling: N/A
· Dry Mode (Moisture Removal, Litre/hr): 2.4
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (Quiet - Super High, dB(A)): 27 / 35 / 39 / 46 / 53 · Sound Level - Heating (Quiet - Super High, dB(A)): 29 / 35 / 41 / 47 / 51
· Current - Cooling [In+Outdoor] (Rated / Max.): 7.7 A / · Current - Heating [In+Outdoor] (Rated / Max.): 8.3 A /
· Air Volume - Cooling (Super High, Litre/sec): 250 · Air Volume - Heating (Super High, Litre/sec): 243
· Refrigerant: R32 · Liquid Pipe Size (OD, mm): 6.35
· Gas Pipe Size (OD, mm): 12.7 · Max. Pipe Length (m): 30
· Max. Pipe Height (m): 15 · Power Supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 750 x 215 x 600 · Weight: 15 kg

MUFZ-KW60VG-A1 - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 53 · Sound Level - Heating (dB(A)): 56
· Air Volume - Cooling (Litre/sec): 250 · Air Volume - Heating (Litre/sec): 243
· Power Supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid Pipe Size (OD, mm): 6.35 · Gas Pipe Size (OD, mm): 12.7
· Max. Pipe Length (m): 30 · Max. Pipe Height (m): 15
· Dimensions (WxDxH, mm): 840 x 330 x 880 · Weight: 54 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]

Downloads

Support

RapidHeat Series