PLA100 Cassette Heat Pump

Large Room System // PLA-M100EA

The large capacity PLA100 4-Way Cassette, with 3D i-See Sensor technology, wide airflow, independent vane direction setting and a new sleek design, provides consistent temperatures throughout the space you need to heat or cool. Perfect for residential rooms or office spaces. This model comes standard with a Deluxe Wireless Controller.

Cooling Capacity10.0 kW
Heating Capacity11.2 kW
Select a Size - R32 Refrigerant
Select a Controller
Optional Outdoor Performance

Features

3D i-See Sensor

The new PLA comes standard with 3D i-See Sensor technology, able to detect the number people in the room, their positions and temperatures. In turn, the 3D i-See Sensor is able to provide the ideal temperature and airflow settings.

Next-Generation R32 Technology

R32 is a refrigerant with just one-third the global warming potential of R410A and has zero ozone depletion potential. R32 offers increased energy efficiency, and is said to be the next generation of refrigerants.

Sleek, Square Desgin

The PLA features a sleek, square design with bevelled edges that provide a compact and modern finish.

Optimum Airflow

With the ability to independently control each wide vane’s airflow, these units are perfect for both residential and office environments, providing controlled airflow to all corners of the space you need to heat or cool. Advanced control of the vanes called “swing airflow” provides even greater heat distribution, periodically moving vanes up and down.

Automatic Air Speed Adjustment

This setting automatically adjusts the air-speed to match the conditions of the room. At the start of heating/cooling, the airflow is set to high-speed to quickly heat or cool the room and once the desired temperature is reached, it decreases for efficient operation.

High and Low Ceiling Modes

Our PLA cassettes are equipped to adjust the airflow volume to match the room height. This ensures that you get comfortable temperature control throughout the room no matter how high your ceiling.

Easy Installation

For improved efficiency during installation, the new PLA features a temporary hanging hook, no need to remove screws on the corner panel or control box, and a lightweight panel which has been reduced in weight by approximately 20% compared to the previous model.

Deluxe Wireless Controller

With a backlit screen for easy viewing, and advanced feature controls exclusive to the PLA Series, including 3D i-See Sensor and individual vane settings, the Deluxe Wireless Controller offers the ultimate in customised comfort.

Specifications

PLA-M100EA // PLA100 Cassette Heat Pump System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 10.0 kW · Capacity - Heating: 11.2 kW
· Capacity - Cooling (min. - max.): 4.9 - 11.4 kW · Capacity - Heating (min. - max.): 4.5 - 14.0 kW
· Power Input - Cooling: 2.43 kW · Power Input - Heating: 2.94 kW
· Star rating - Cooling: NA · Star rating - Heating: NA
· EER / COP: 4.11 / 3.80 · AEER / ACOP: 3.95 / 3.68
· Current - Cooling [In+Outdoor] (Rated): 11.10 A · Current - Heating [In+Outdoor] (Rated): 14.02 A
· Current (Max.): 27.96 A
Performance
· Operation Range - Cooling: -5 / +52 degC · Operation Range - Heating: -20 / +21 degC

PUZ-ZM100VKA2-A.TH - R32 Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -5 / +52 degC · Operation Range - Heating: -20 / +21 degC
· Sound Level - Cooling (dB(A)): 49 · Sound Level - Heating (dB(A)): 51
· Air Volume - Cooling (Litre/sec): 1833 · Air Volume - Heating (Litre/sec): 1833
· Power Supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid Pipe Size (OD, mm): 9.52 · Gas Pipe Size (OD, mm): 15.88
· Max. Pipe Length (m): 75 · Max. Pipe Height (m): 30
· Dimensions (WxDxH, mm): 1050 x 330 x 1338 · Weight: 116 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]

Downloads

Support

4-Way Large Cassette