Home Energy Recovery Ventilation

SKU-50RJ-E

In-Ceiling Mounted Fresh Air Energy Recovery Ventilation System. Recovers heat in Winter or cool air in Summer. Simultaneously remove stale air from the room whilst replacing it with filtered fresh outdoor air, at the same time recovering the energy from the exhausted stale air. This energy is recovered by using a revolutionary Lossnay core that is made from specially treated paper. Operated by a simple to use wall mounted controller which indicates the indoor air, outdoor air and incoming fresh air temperatures.

Discontinued Product

Features

Lossnay Fresh Air Energy Recovery

The most effective and energy-efficient way to ventilate your home. The Lossnay Fresh Air Energy Recovery system sets a new standard in domestic ventilation by recovering heat from the air inside your home and transferring it to fresh, dry air introduced from outside. Lossnay ensures the air in your home stays fresh, clean and dry. And because you’re retaining the warmth, you’ll save on your heating bill as well.

Watch an example of a Lossnay Ventilation System

Subtle design and a quieter home

Like all products from Mitsubishi Electric, the Lossnay system is designed to make life more comfortable. Fan operation is whisper quiet; while the discreet air vents will keep your home looking just the way you like it.

And if you live near busy roads or an airport, noise won’t be a problem. Common ventilation systems funnel the outside noise into your home - Lossnay’s core actually reduces noise by up to 50% for more relaxed indoor living.

Installation example for a healthier, drier home!

Example of a 4 outlet Lossnay Energy Recovery Ventilation System installed in your home with a simple to use controller, just set it and forget - it will do the rest. This system is capable of supplying fresh air whilst reducing dampness, toxins and dust from your home.

This 4 outlet Lossnay Energy Recovery Ventilation Package would be ideal for ventilating an average New Zealand home.


Extracts air

Extracts stale air removing toxins and reducing humidity.

Supplies fresh air

Supplies fresh air increasing the oxygen levels in the home and preventing the build up of moisture.

Lossnay energy recovery unit

Recovers the heat from the outgoing air to preheat the incoming air, saving you money.

Lossnay will ensure the air in your home stays fresh, clean and dry. And because you’re retaining the warmth, you’ll save on your heating bill as well.

No ventilation system currently sold in New Zealand heats unless fitted with an extra heating system. To accompany the fresh clean air that Lossnay will supply to your home, we suggest using a Mitsubishi Electric Heat Pump to warm the air in your home, providing you with a healthy and comfortable living environment all year round.

For a healthier home

Operational reports have shown that Lossnay’s filtering reduces the level of dust in your home - so there’s less need for dusting and general cleaning, which can only be a good thing! What’s more, lingering food smells are much more manageable, while constant fresh air circulation helps to minimise the buildup of moisture

Moisture Removal

Lossnay effectively removes moisture from your home by directly removing the stale air that causes condensation via the Lossnay core... which manages both energy recovery and moisture levels.

Specifications

Heat exchange system: Air to Air total heat exchange (sensible heat + latent heat exchange)
Heat exchange element material: Partition spacing plate – treated paper
Operating range of outdoor and indoor: OA temperature –10°C to +40°C, 80% RH
Power Supply: 230V +/- 10% / Single Phase / 50 Hz
Dimensions (HxWxD, mm): 391 x 871 x 544
Weight: 35 kg
Starting current: 2 A
Duct size: 200mm (Insulated)
Dehumidification: 2.62 l/hr
At Fan speeds
Current (Low - Mid - High): 0.39 - 0.64 - 1.00 A
Power consumption (Low - Mid - High): 89 - 146 - 226 W
Air Volume - Cooling (Low - Mid - High): 67 - 108 - 139 l/s
External Static Pressure (Low - Mid - High): 26 - 33 - 38 Pa
Indoor Sound (Low - Mid - High)***: 26 - 33 - 38 dB(A)
Notes
*: Total external static pressure maximum includes Return Air Fan. OA = Outside Air RH = Return Humidity
**: Dehumidification measurements are based on Outdoor Air Temperature 0°C (Dry Bulb) and 80% RH and Indoor Air Temperature 20°C (Dry Bulb) and 60% RH at High Fan Speed 139 l/sec.
***: Noise dB, (measured at 1.5m under panel)
Lossnay Ventilation Complies with Standards: AS/NZS60335.2.80 and AS/NZS CISPR14.1

Dimensions

Note: Dimension unit (mm).