Power Inverter Wall Mounted

Large Room System // PKA-RP71KALR1.TH

High Wall indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 1170 x 295 x 365. Weight: 21kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88.

Cooling Capacity7.1 kW
Heating Capacity8.0 kW

Specifications

· Function: Cooling/Heating · Type: Single Split, Power Inverter
· Capacity - Cooling: 7.1 kW · Capacity - Heating: 8.0 kW
· Capacity - Cooling (min. - max.): 3.3 - 8.1 kW · Capacity - Heating (min. - max.): 3.5 - 10.2 kW
· Power Input - Cooling: 1.96 kW · Power Input - Heating: 2.13 kW
· EER / COP: 3.62 / 3.76 · AEER / ACOP: 3.42 / 3.57
· Operation Range - Cooling: -5 (-15*) / +46°C · Operation Range - Heating: -20 / +21°C
· Airflow (Lo-Hi, Litre/sec): 300-333-367 · Sound Level (Lo-Hi, dB(A)): 39-42-45
· Current Indoor - Cooling (Running / Starting): 0.43 / 0.80 A · Current Indoor - Heating (Running / Starting): 0.43 / 0.80 A
· Power Supply: 230V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid Pipe Size (OD, mm): 9.52 · Gas Pipe Size (OD, mm): 15.88
· Max. Pipe Length (m): 50 · Max. Pipe Height (m): 30
· Dimensions (WxDxH, mm): 1170 x 295 x 365 · Weight: 21 kg
· Note: Capacity ratings are based on the deluxe outdoor unit PUHZ-RP71VHA only. · [*]: -15°C in cooling when using an optional outdoor air outlet guide PAC-SG59SG-E.

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]

Downloads