Lossnay LGH-RVS Sensible Heat Recovery Ventilation

Filters Silencer Ducts Accessories Standard Filter Medium-efficiency Filter High-efficiency Filter A lineup of three types of filters offers optimum indoor air quality solutions! All filters are ISO and EN779:2012 certified, and can be easily installed in the units. Maintenance and exchanges can also be performed easily, simply by opening the maintenance panel. In facilities and applications requiring quiet operations, the silencer duct that reduces noise levels is the ideal solution. It contains glass wool and attenuates sound power by absorbing the noise from the airflow or operation of the unit. 1. Figures on the chart above are based on the comparison with a general steel duct of the same length. 2. The silencer is placed on just before the outlet during the measurement. 3. When the air ow rate differs, the insertion loss is also different from the chart above. 4. Figures on the chart above are at (No-weighted) values. Filter Lossnay Classification Filter material ISO 16890 (2016) EN779 (2012) Model name Included piece/set Applicable model Required set/unit 2 LGH-50RVS-E 1 PZ-S50RF-E 2 LGH-80RVS-E 1 PZ-S80RF-E 2 LGH-100RVS-E 1 PZ-S100RF-E Non-woven fabrics Coarse 50% G3 Filter Lossnay Classification Filter material ISO 16890 (2016) EN779 (2012) Model name Included piece/set Applicable model Required set/unit 2 LGH-50RVS-E 1 PZ-S50RFM-E 2 LGH-80RVS-E 1 PZ-S80RFM-E 2 LGH-100RVS-E 1 PZ-S100RFM-E Pleated lter ePM10 80% M6 Filter Lossnay Classification Filter material ISO 16890 (2016) EN779 (2012) Model name Included piece/set Applicable model Required set/unit 2 LGH-50RVS-E 1 PZ-S50RFH-E 2 LGH-80RVS-E 1 PZ-S80RFH-E 2 LGH-100RVS-E 1 PZ-S100RFH-E Pleated lter ePM10 90% ePM2.5 75% ePM1 65% F8 Model Direction Discharge Suction Discharge Suction Air flow 500 m3/h 650 m3/h 500 m3/h 650 m3/h 800 m3/h 1000 m3/h 800 m3/h 1000 m3/h 62.5Hz Attenuation of sound power level [dB] for center frequency 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 0 1 4 7 13 18 16 9 0 1 3 8 12 17 14 6 0 1 4 8 11 17 14 8 0 0 3 7 10 11 12 5 0 2 4 12 22 21 14 13 0 1 4 12 22 20 14 13 0 3 5 12 18 14 11 4 0 2 4 12 17 16 13 8 PZ-200SS-E PZ-250SS-E S-175-1-CA695-A-NK-2105-IP www.MitsubishiElectric.com PUBLISHED DEC 2023 www.mitsubishi-electric.co.nz | 0800 784 382 Please note: When deciding on the best place to position the Lossnay Ventilation System, care needs to be taken to not have incoming air intake near or close to a wood burner flue.

RkJQdWJsaXNoZXIy MTg0ODUyNA==