Lossnay LGH-RVS Sensible Heat Recovery Ventilation

Unit: mm 400 350 300 250 200 150 100 50 0 95 90 85 80 75 70 65 60 55 0 200 100% Temp. exchange ef ciency Φ250 duct straight 123m Φ250 duct straight 110m Φ250 duct straight 60m 75% 50% 25% 400 600 800 Air ow 1,000 1,200 1,400 1,600 [m3/h] 0 50 100 150 200 250 300 350 400 [L/s] External static pressure [Pa] Exchange ef ciency [%] 400 350 300 250 200 150 100 50 0 95 90 85 80 75 70 65 60 55 0 200 400 600 800 Air ow 1,000 1,200 1,400 [m3/h] 0 50 100 150 200 250 300 350 [L/s] External static pressure [Pa] Exchange ef ciency [%] 100% Temp. exchange ef ciency Φ250 duct straight 175m Φ250 duct straight 100m Φ250 duct straight 60m 75% 50% 25% Inspection opening 450 ×450 or more Heat exchanger, Air lter, High-Ef ciency lter, Fan,drain pan maintenance space In case of xed ceiling (not grid ceiling), 150mm or more for drain maintenance Air supply fan Control box Air exhaust fan Alternative duct position Bypass damper plate Ceiling suspension xture (4-13 × 20 oval) Power supply opening High-Ef ciency lter(sold separately) position Heat exchanger (Lossnay core) Air lters Drain catch basin Back ow stopper Drain pipe(1/100 gradient) (Drain pipe can be set preferable direction) O.D Φ32 (VP25) Filter maintenance cover(Upper) Drain pan,cores,motors maintenance cover(Lower) Ceiling 1179 161 More than 600 150 to 250 1224 910 115 45 465 55 1185 82 82 Φ242 Φ258 20 1279 64 153 161 RA (return air) SA (supply air) EA (exhaust air outlet) OA (outside air intake) 165 Inspection opening 450 ×450 or more Heat exchanger, Air lter, High-Ef ciency lter, Fan,drain pan maintenance space In case of xed ceiling (not grid ceiling), 150mm or more for drain maintenance Air supply fan Control box Air exhaust fan Alternative duct position Bypass damper plate Ceiling suspension xture (4-13 × 20 oval) O.D Φ32 (VP25) High-Ef ciency lter(sold separately) position Heat exchanger (Lossnay core) Air lters Power supply opening Drain catch basin Back ow stopper Drain pipe (1/100 gradient) (Drain pipe can be set preferable direction) Drain pan,cores,motors maintenance cover (Lower) Ceiling Filter maintenance cover(Upper) 1179 161 More than 600 150 to 250 997 683 115 45 465 55 82 82 Φ242 Φ258 20 1051 64 153 161 RA (return air) SA (supply air) EA (exhaust air outlet) OA (outside air intake) 1185 165 Specifications LGH-100RVS-E Unit: mm Characteristic Curves Dimensions LGH-80RVS-E Characteristic Curves Dimensions Weight 73kg (89kg with maximum drain water) 220-240V/50Hz, 220V/60Hz 100% 75% 50% 25% Test condition 445 225 100 35 ISO 16494 Temp. exchange ef ciency is winter condition 1000 750 500 250 278 208 139 69 1.60 1.08 0.72 0.50 190 107 48 12 82.0 84.0 86.0 90.0 37.0 32.0 24.0 18.0 A-weighted sound pressure level @1.5m off from the center of the unit in an anechoic chamber 5 Tracer gas method @100% air ow (prEN308) 10MΩ or more AC 1000V 1 minute 4.20 6.1A @10ms, 3.6A@100ms Electrical power supply Fan speed Input power [W] Airflow [m3/h] [L/s] Specific fan power [W/(L/s)] External static pressure [Pa] Temp. exchange efficiency [%] Noise [dB] Exhaust air transfer ratio [%] Insulation resistance Dielectric strength Maximum current [A] Inrush current [A] Weight 63kg (77kg with maximum drain water) 220-240V/50Hz, 220V/60Hz 100% 75% 50% 25% Test condition 325 175 85 32 ISO 16494 Temp. exchange ef ciency is winter condition 800 600 400 200 222 167 111 56 1.46 1.05 0.77 0.58 170 96 43 11 82.0 84.0 86.0 90.0 36.0 30.0 25.0 18.0 A-weighted sound pressure level @1.5m off from the center of the unit in an anechoic chamber 5 Tracer gas method @100% air ow (prEN308) 10MΩ or more AC 1000V 1 minute 3.70 6.1A @10ms, 3.6A@100ms Electrical power supply Fan speed Input power [W] Airflow [m3/h] [L/s] Specific fan power [W/(L/s)] External static pressure [Pa] Temp. exchange efficiency [%] Noise [dB] Exhaust air transfer ratio [%] Insulation resistance Dielectric strength Maximum current [A] Inrush current [A]

RkJQdWJsaXNoZXIy MTg0ODUyNA==