Optional Parts For more information on Mitsubishi Electric Heat Pumps, please visit www.mitsubishi-electric.co.nz or call our Customer Service Team on 0800 784 382 AUCKLAND BRANCH Unit 1, 4 Walls Road PO Box 12726 Penrose, Auckland 1642 Phone (09) 526 9347 CHRISTCHURCH BRANCH 44 Halwyn Drive PO Box 16904 Hornby, Christchurch 8441 Phone (03) 341 2837 WELLINGTON HEAD OFFICE 1 Parliament Street PO Box 30772 Lower Hutt 5040 Phone (04) 560 9147 Fax (04) 560 9133 Black Diamond Technologies Exclusive distributor of Mitsubishi Electric products in NZ Be sure to ask for Mitsubishi Electric. Other brands share the 3-diamond logo, however they are separate to the Mitsubishi Electric brand and cannot supply the models, features or guarantees outlined in this brochure. | All models, features and specifications are subject to change and amendment at anytime. Printed August 2018. Notes: *1.Under Normal heating conditions at the outdoor temp, 16°CDB/12°CWB(60.8°FDB/53.6°FWB), the outlet water temperature 65°C(149°F), and the inlet water temperature 17°C(62.6°F) *2.Under Normal heating conditions at the outdoor temp, 7°CDB/6°CWB(44.6°FDB/42.8°FWB), the outlet water temperature 65°C(149°F), and the inlet water temperature 9°C(48.2°F) *3.Under Normal heating conditions at the outdoor temp, 7°CDB/6°CWB(44.6°FDB/42.8°FWB), the outlet water temperature 65°C(149°F), and the inlet water temperature 15°C(59.0°F) *4.Under Normal heating conditions at the outdoor temp, 7°CDB/6°CWB(44.6°FDB/42.8°FWB), when the unit is set to the “Capacity Priority“ mode through the dry NC-contact. *Due to continuing improvements, specifications may be subject to change without notice *Do not use steel pipes as water pipes. *Keep the water circulated at all times. Blow the water out of the pipes if the unit will not be used for an extended period time. *Do not use ground water or well water *Do not install the unit in an environment where the wet bulb temperature exceeds 32°C *The water circuit must use the closed circuit *There is a possibility that the unit may abnormally stop when it operates outside its operating range. Provide backup (ex. boiler start with error display output signal (blue CN511 1-3)) for abnormal stop. UNIT CONVERTER BTU/h = kW x 3,412 cfm =m3/min x 35.31 lbs = kg/0.4536 QAHV-N560YA-HPB Power Source 3-phase 4-wire 380-400-415V 50Hz Capacity *1 kW 40 Btu/h 136480 Power Input kW 10.31 Current Input A 17.8-16.9-16.3 COP(kW/kW) 3.88 Capacity *2 kW 40 Btu/h 136480 Power Input kW 10.97 Current Input A 20.0-19.0-18.3 COP(kW/kW) 3.65 Capacity *3 kW 40 Btu/h 136480 Power Input kW 11.6 Current Input A 20.4-19.4-18.7 COP(kW/kW) 3.44 Maximum Current Input *4 A 28.8-27.4-26.4 Allowable External Pump Head 77kPa Temperature Range Outlet Water Temp 55–90°C (when the secondary side control is enabled: 55–80°C) Outdoor Temp D.B. -25~43°C Sound Pressure Level (measured 1m below the unit in an anechoic room) *1 dB(A) 56 Water Pipe Diameter and Type Inlet mm(in.) 19.05(Rc 3/4"), screw pipe Outlet mm(in.) 19.05(Rc 3/4"), screw pipe External Finish Acrylic painted steel plate <MUNSELL 5Y 8/1 or similar> External Dimension H x W x D mm 1837(1777 not including legs) x 1220 x 760 Net Weight kg(lbs) 400(882) Design Pressure R744 MPa 14 Water MPa 1.0 Heat Exchanger Water-side Copper tube coil Air-side Plate fin and copper tube Compressor Type Inverter scroll hermetic compressor Maker MITSUBISHI ELECTRIC CORPORATION Motor Output kW 11.0 Case Heater kW 0.045 FAN Air Flow Rate m3/min 220 L/s 3666 Type x Quantity Propeller fan Control, Driving Mechanism Inverter-control, Direct-driven by motor Motor Output kW 0.92 HIC (HIC: Heat inter-changer) Circuit Copper pipe Protection High Pressure Protection High pres.Sensor & High pres. Switch at 14MPa(643psi) Inverter Circuit Overheat and overcurrent protection Compressor Overheat protection Fan Motor Thermal switch Defrosting Method Auto-defrost mode (Hot gas) Refrigerant Type x Original Charge CO2 (R744) 6.5kg Remote Controller PAR-W31MAA-J Representative Water Temperature Sensor TW-TH16-E
RkJQdWJsaXNoZXIy MTg0ODUyNA==